Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Appl Opt ; 63(10): 2694-2703, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38568554

RESUMEN

Accurate assessment of corneal curvatures using frequency domain optical coherence tomography (OCT) with galvanometer scanners remains challenging due to the well-known scan field distortion. This paper presents an algorithm and software for correcting the distortion using only two simple measurements in which a readily available standard sphere is positioned in different depths in front of the OCT scanner. This offers a highly accessible and easily reproducible method for the field distortion correction (FDC). The correction was validated by measuring different spherical phantoms and conducting corneal curvature measurements of ex vivo porcine corneas using a commercial spectral-domain OCT system and a clinically approved swept-source OCT as a reference instrument. Thus, the error in radius measurements of spherical phantoms was reduced by >90% and astigmatism by >80% using FDC. In explanted porcine eyes, the error in astigmatism measurements with the Telesto was reduced by 75% for power and 70% for angle. The best fitting sphere radius was determined up to a deviation of 0.4% from the Anterion. This paper describes a correction algorithm for OCT immanent distortion that is applicable to any scanning OCT setup and enables precise corneal curvature measurements. The MATLAB software for the FDC is publicly available on GitHub.


Asunto(s)
Astigmatismo , Tomografía de Coherencia Óptica , Animales , Porcinos , Algoritmos , Programas Informáticos , Córnea/diagnóstico por imagen
2.
Opt Express ; 32(4): 5809-5825, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38439298

RESUMEN

Circumferential scanning in endoscopic imaging is crucial across various disciplines, and optical coherence tomography (OCT) is often the preferred choice due to its high-speed, high-resolution, and micron-scale imaging capabilities. Moreover, real-time and high-speed 3D endoscopy is a pivotal technology for medical screening and precise surgical guidance, among other applications. However, challenges such as image jitter and non-uniform rotational distortion (NURD) are persistent obstacles that hinder real-time visualization during high-speed OCT procedures. To address this issue, we developed an innovative, low-cost endoscope that employs a brushless DC motor for scanning, and a sensorless technique for triggering and synchronizing OCT imaging with the scanning motor. This sensorless approach uses the motor's electrical feedback (back electromotive force, BEMF) as a virtual Hall sensor to initiate OCT image acquisition and synchronize it with a Fourier Domain Mode-Locked (FDML)-based Megahertz OCT system. Notably, the implementation of BEMF-triggered OCT has led to a substantial reduction in image jitter and NURD (<4 mrad), thereby opening up a new window for real-time visualization capabilities. This approach suggests potential benefits across various applications, aiming to provide a more accurate, deployable, and cost-effective solution. Subsequent studies can explore the adaptability of this system to specific clinical scenarios and its performance under practical endoscopic conditions.

3.
Opt Express ; 31(20): 33500-33517, 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37859131

RESUMEN

Holographic optical coherence tomography (OCT) is a powerful imaging technique, but its ability to reveal low-reflectivity features is limited. In this study, we performed holographic OCT by incoherently averaging volumes with changing diffuse illumination of numerical aperture (NA) equal to the detection NA. While the reduction of speckle from singly scattered light is only modest, we discovered that speckle from multiply scattered light can be arbitrarily reduced, resulting in substantial improvements in image quality. This technique also offers the advantage of suppressing noises arising from spatial coherence, and can be implemented with a partially spatially incoherent light source for further mitigation of multiple scattering. Finally, we show that although holographic reconstruction capabilities are increasingly lost with decreasing spatial coherence, they can be retained over an axial range sufficient to standard OCT applications.

4.
IEEE Trans Biomed Eng ; 70(11): 3064-3072, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37167045

RESUMEN

OBJECTIVE: Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. METHODS: We present a miniaturized dual-fiber OCE probe of 1 mm diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. RESULTS: Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of 0.15 ms-1 and 0.02 ms-1 for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to 0.54 ms-1 and 0.03 ms-1 for single-fiber and dual-fiber OCE, respectively. CONCLUSION: We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. SIGNIFICANCE: This study introduces an approach for robust elasticity quantification from within the tissue.

5.
Am J Physiol Lung Cell Mol Physiol ; 323(4): L423-L430, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35997279

RESUMEN

Asthma is one of the most common chronic diseases. Mucus overproduction is consistently linked to asthma morbidity and mortality. Despite the knowledge of the importance of mucus, little data exist on how mucus is transported in asthma and the immediate effects of therapeutic intervention. We therefore used microscopic optical coherence tomography (mOCT) to study spontaneous and induced mucus transport in an interleukin-13 (IL-13)-induced asthma mouse model and examined the effects of isotonic (0.9% NaCl) and hypertonic saline (7% NaCl), which are used to induce mucus transport in cystic fibrosis. Without intervention, no bulk mucus transport was observed by mOCT and no intraluminal mucus was detectable in the intrapulmonary airways by histology. Administration of ATP-γ-S induced mucus secretion into the airway lumen, but it did not result in bulk mucus transport in the trachea. Intraluminal-secreted immobile mucus could be mobilized by administration of isotonic or hypertonic saline but hypertonic saline mobilized mucus more reliably than isotonic saline. Irrespective of saline concentration, the mucus was transported in mucus chunks. In contrast to isotonic saline solution, hypertonic saline solution alone was able to induce mucus secretion. In conclusion, mOCT is suitable to examine the effects of mucus-mobilizing therapies in vivo. Although hypertonic saline was more efficient in inducing mucus transport, it induced mucus secretion, which might explain its limited benefit in patients with asthma.


Asunto(s)
Asma , Interleucina-13 , Adenosina Trifosfato , Animales , Asma/diagnóstico por imagen , Asma/tratamiento farmacológico , Microscopía Intravital , Ratones , Moco , Solución Salina , Solución Salina Hipertónica/farmacología , Solución Salina Hipertónica/uso terapéutico , Cloruro de Sodio , Tomografía de Coherencia Óptica
6.
Biomed Opt Express ; 13(6): 3211-3223, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35781952

RESUMEN

In the imaging of airway tissue, optical coherence tomography (OCT) provides cross-sectional images of tissue structures, shows cilia movement and mucus secretion, but does not provide sufficient contrast to differentiate individual cells. By using fast sequences of microscopic resolution OCT (mOCT) images, OCT can use small signal fluctuations to overcome lack in contrast and speckle noise. In this way, OCT visualizes airway morphology on a cellular level and allows the tracking of the dynamic behavior of immune cells, as well as mucus transport and secretion. Here, we demonstrate that mOCT, by using temporal tissue fluctuation as contrast (dynamic mOCT), provides the possibility to study physiological and pathological tissue processes in vivo.

7.
Front Med (Lausanne) ; 9: 885187, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35721092

RESUMEN

Non-invasive spatially resolved functional imaging in the human retina has recently attracted considerable attention. Particularly functional imaging of bipolar and ganglion cells could aid in studying neuronal activity in humans, including an investigation of processes of the central nervous system. Recently, we imaged the activity of the inner neuronal layers by measuring nanometer-size changes of the cells within the inner plexiform layer (IPL) using phase-sensitive optical coherence tomography (OCT). In the IPL, there are connections between the neuronal cells that are dedicated to the processing of different aspects of the visual information, such as edges in the image or temporal changes. Still, so far, it was not possible to assign functional changes to single cells or cell classes in living humans, which is essential for studying the vision process. One characteristic of signal processing in the IPL is that different aspects of the visual impression are only processed in specific sub-layers (strata). Here, we present an investigation of these functional signals for three different sub-layers in the IPL with the aim to separate different properties of the visual signal processing. Whereas the inner depth-layer, closest to the ganglion cells, exhibits an increase in the optical path length, the outer depth-layer, closest to the bipolar cell layer, exhibits a decrease in the optical path length. Additionally, we found that the central depth is sensitive to temporal changes, showing a maximum response at a stimulation frequency of around 12.5 Hz. The results demonstrate that the signals from different cell types can be distinguished by phase-sensitive OCT.

8.
BMJ Open ; 12(6): e055082, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35760534

RESUMEN

OBJECTIVES: Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an improved prototype for patients with AMD and focusses on device operability and diagnostic accuracy compared with established spectral-domain OCT (SD-OCT). DESIGN: Prospective single-arm diagnostic accuracy study. SETTING: Tertiary care centre (University Eye Clinic). PARTICIPANTS: 46 patients with age-related macular degeneration. INTERVENTIONS: Patients received short training in device handling and then performed multiple self-scans with the SELFF-OCT according to a predefined protocol. Additionally, all eyes were examined with standard SD-OCT, performed by medical personnel. All images were graded by at least 2 masked investigators in a reading centre. PRIMARY OUTCOME MEASURE: Rate of successful self-measurements. SECONDARY OUTCOME MEASURES: Sensitivity and specificity of SELFF-OCT versus SD-OCT for different biomarkers and necessity for antivascular endothelial growth factor (anti-VEGF) treatment. RESULTS: In 86% of all examined eyes, OCT self-acquisition resulted in interpretable retinal OCT volume scans. In these patients, the sensitivity for detection of anti-VEGF treatment necessity was 0.94 (95% CI 0.79 to 0.99) and specificity 0.95 (95% CI 0.82 to 0.99). CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination in most patients, and it could become a valuable tool for retinal home monitoring in the future. Improvements are in progress to reduce device size and to improve handling, image quality and success rates. TRIAL REGISTRATION NUMBER: DRKS00013755, CIV-17-12-022384.


Asunto(s)
Degeneración Macular , Tomografía de Coherencia Óptica , Estudios Transversales , Humanos , Degeneración Macular/diagnóstico por imagen , Degeneración Macular/tratamiento farmacológico , Estudios Prospectivos , Autoexamen , Tomografía de Coherencia Óptica/métodos
9.
Transl Vis Sci Technol ; 11(5): 28, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35622381

RESUMEN

Purpose: Microscopic optical coherence tomography (mOCT) has an imaging resolution of 1 µm in all voxel dimensions, but individual epithelial cells are difficult to resolve due to lack of scattering contrast. Adding dynamic contrast processing to mOCT (dmOCT) results in color images that enable visualization of individual cells and possibly give information on cellular function via the calculation of a motility coefficient. We propose this technique as a novel method of evaluating the ocular surface after exposure to a toxic chemical, benzalkonium chloride (BAK). Methods: Ex vivo cross-section images were acquired with a custom-built, frequency-domain mOCT system. Eyes were explanted from healthy adult C57BL/6 mice and imaged every 30 minutes with five sets of dmOCT scans at each imaging time. Total epithelium and stroma thicknesses were measured from a single mOCT B-scan, and measures of color changes (hue) and the motility coefficient were acquired from dmOCT scans. Results: After 30-minute exposures to 0.005% BAK, local motility decreased and total epithelium thickness increased compared to controls. For basal epithelium cells, local motility decreased after 60-minute exposures, and the hue shifted red after 90-minute exposures. Stroma thickness did not significantly swell until 150-minute exposures to BAK. Conclusions: dmOCT allows us to view the behavior of the cornea epithelium under toxic stress due to BAK, revealing parallel swelling of the extracellular matrix and changes in local subcellular motion. Translational Relevance: The evaluation of the cornea epithelium using dmOCT is helpful to our understanding of the toxic effects of BAK.


Asunto(s)
Epitelio Corneal , Animales , Compuestos de Benzalconio , Epitelio Corneal/diagnóstico por imagen , Ratones , Ratones Endogámicos C57BL , Tomografía de Coherencia Óptica/métodos
10.
Opt Lett ; 47(5): 1198-1201, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35230326

RESUMEN

Full-field swept-source optical coherence tomography (FF-SS-OCT) and laser Doppler holography (LDH) are two holographic imaging techniques presenting unique capabilities for ophthalmology. We report on interlaced FF-SS-OCT and LDH imaging with a single instrument. Effectively, retinal blood flow and pulsation could be quasi-simultaneously monitored. This instrument holds potential for a wide scope of ophthalmic applications.


Asunto(s)
Holografía , Tomografía de Coherencia Óptica , Angiografía , Rayos Láser , Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
11.
Biomed Opt Express ; 12(10): 6024-6039, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34745719

RESUMEN

Volumetric imaging of dynamic processes with microscopic resolution holds a huge potential in biomedical research and clinical diagnosis. Using supercontinuum light sources and high numerical aperture (NA) objectives, optical coherence tomography (OCT) achieves microscopic resolution and is well suited for imaging cellular and subcellular structures of biological tissues. Currently, the imaging speed of microscopic OCT (mOCT) is limited by the line-scan rate of the spectrometer camera and ranges from 30 to 250 kHz. This is not fast enough for volumetric imaging of dynamic processes in vivo and limits endoscopic application. Using a novel CMOS camera, we demonstrate fast 3-dimensional OCT imaging with 600,000 A-scans/s at 1.8 µm axial and 1.1 µm lateral resolution. The improved speed is used for imaging of ciliary motion and particle transport in ex vivo mouse trachea. Furthermore, we demonstrate dynamic contrast OCT by evaluating the recorded volumes rather than en face planes or B-scans. High-speed volumetric mOCT will enable the correction of global tissue motion and is a prerequisite for applying dynamic contrast mOCT in vivo. With further increase in imaging speed and integration in flexible endoscopes, volumetric mOCT may be used to complement or partly replace biopsies.

12.
Int J Med Robot ; 17(6): e2327, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34480406

RESUMEN

BACKGROUND: In endovascular aneuysm repair (EVAR) procedures, medical instruments are currently navigated with a two-dimensional imaging based guidance requiring X-rays and contrast agent. METHODS: Novel approaches for obtaining the three-dimensional instrument positions are introduced. Firstly, a method based on fibre optical shape sensing, one electromagnetic sensor and a preoperative computed tomography (CT) scan is described. Secondly, an approach based on image processing using one 2D fluoroscopic image and a preoperative CT scan is introduced. RESULTS: For the tracking based method, average errors from 1.81 to 3.13 mm and maximum errors from 3.21 to 5.46 mm were measured. For the image-based approach, average errors from 3.07 to 6.02 mm and maximum errors from 8.05 to 15.75 mm were measured. CONCLUSION: The tracking based method is promising for usage in EVAR procedures. For the image-based approach are applications in smaller vessels more suitable, since its errors increase with the vessel diameter.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Fluoroscopía , Humanos , Imagenología Tridimensional
13.
Opt Lett ; 46(14): 3456-3459, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34264237

RESUMEN

Stimulated Raman scattering (SRS) microscopy for biomedical analysis can provide a molecular localization map to infer pathological tissue changes. Compared to spontaneous Raman, SRS achieves much faster imaging speeds at reduced spectral coverage. By targeting spectral features in the information dense fingerprint region, SRS allows fast and reliable imaging. We present time-encoded (TICO) SRS microscopy of unstained head-and-neck biopsies in the fingerprint region with molecular contrast. We combine a Fourier-domain mode-locked (FDML) laser with a master oscillator power amplifier (MOPA) to cover Raman transitions from 1500-1800cm-1. Both lasers are fiber-based and electronically programmable making this fingerprint TICO system robust and reliable. The results of our TICO approach were cross-checked with a spontaneous Raman micro-spectrometer and show good agreement, paving the way toward clinical applications.


Asunto(s)
Microscopía Óptica no Lineal , Faringe , Humanos , Rayos Láser , Microscopía , Espectrometría Raman
14.
Front Immunol ; 12: 692222, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34248987

RESUMEN

Imaging techniques have evolved impressively lately, allowing whole new concepts like multimodal imaging, personal medicine, theranostic therapies, and molecular imaging to increase general awareness of possiblities of imaging to medicine field. Here, we have collected the selected (3D) imaging modalities and evaluated the recent findings on preclinical and clinical inflammation imaging. The focus has been on the feasibility of imaging to aid in inflammation precision medicine, and the key challenges and opportunities of the imaging modalities are presented. Some examples of the current usage in clinics/close to clinics have been brought out as an example. This review evaluates the future prospects of the imaging technologies for clinical applications in precision medicine from the pre-clinical development point of view.


Asunto(s)
Inflamación/diagnóstico por imagen , Animales , Diagnóstico por Imagen , Humanos
15.
Ophthalmol Sci ; 1(4): 100085, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36246942

RESUMEN

Purpose: To assess the efficacy of an instrument-integrated OCT (iiOCT)-based distance sensor during robotic vitreoretinal surgery using the Preceyes Surgical System (PSS; Preceyes B.V.). Design: Single-center interventional study. Participants: Patients requiring vitreoretinal surgery. Methods: Five patients were enrolled. Standard preoperative OCT images were obtained. After vitrectomy, a predefined set of actions was performed using the iiOCT-based sensor. Images then were processed to assess the signal-to-noise ratio (SNR) at various angles to the retina and at different distances between the instrument tip and the retinal surface. Preoperative and intraoperative OCT images were compared qualitatively and quantitatively. Main Outcomes Measures: The feasibility in performing surgical tasks using the iiOCT-based sensor during vitreoretinal surgery, the SNR when imaging the retina, differences among intraoperative and preoperative OCT images, and characteristics of intraoperative retinal movements detected with the iiOCT-based probe. Results: Surgeons were able to perform all the tasks but one. The PSS was able to maintain a fixed distance. The SNR of the iiOCT-based sensor signal was adequate to determine the distance to the retina and to control the PSS. Analysis of iiOCT-based sensor A-scans identified 3 clearly distinguishable retinal layers, including the inner retinal boundary and the interface at the retinal pigment epithelium-Bruch's membrane. Thickness values differed by less than 5% from that measured by preoperative OCT, indicating its accuracy. The Fourier analysis of iiOCT-based sensor recordings identified anteroposterior retinal movements attributed to heartbeat and respiration. Conclusions: This iiOCT-based sensor was tested successfully and promises reliable use during robot-assisted surgery. An iiOCT-based sensor is a promising step toward OCT-guided robotic retinal surgery.

16.
Graefes Arch Clin Exp Ophthalmol ; 259(6): 1503-1511, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33346888

RESUMEN

PURPOSE: The treatment guidelines for many macular diseases rely on frequent monitoring with optical coherence tomography (OCT). However, the burden of frequent disease control leads to low therapy adherence in real life. OCT home monitoring would address this issue but requires an inexpensive and self-operable device. With self-examination low-cost full-field OCT (SELFF-OCT), our group has introduced a novel technology that may fulfill both requirements. In this pilot study, we report the initial experiences with a clinical prototype. METHODS: Fifty-one patients with different macular diseases were recruited in a cross-sectional study. The most common diseases were age-related macular degeneration (AMD; 39/51), diabetic macular edema (DME; 6/51), and retinal vein occlusion (RVO; 3/51). Patients received a short training in device usage and then performed multiple self-scans with the SELFF-OCT device. For comparison, scans with a standard clinical spectral domain (SD-)OCT were taken. RESULTS: After a brief training, 77% of the patients were able to successfully acquire images that were clinically gradable. No significant influence on success could be found for age (p = 0.08) or BCVA (p = 0.97). Relevant disease biomarkers in the most common retinal diseases could be detected. CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination and in the future could be used for retinal home monitoring. Future improvements in technology are expected to improve success rates and image quality. TRIAL REGISTRATION: The Trial was registered in the German Trial Register under the number DRKS00013755 on 14.03.2018.


Asunto(s)
Retinopatía Diabética , Edema Macular , Enfermedades de la Retina , Estudios Transversales , Humanos , Edema Macular/diagnóstico , Proyectos Piloto , Autoexamen , Tomografía de Coherencia Óptica
17.
J Clin Med ; 9(10)2020 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-33053724

RESUMEN

Caries, the world's most common chronic disease, remains a major cause of invasive restorative dental treatment. To take advantage of the diagnostic potential of optical coherence tomography (OCT) in contemporary dental prevention and treatment, an intraorally applicable spectral-domain OCT probe has been developed based on an OCT hand-held scanner equipped with a rigid 90°-optics endoscope. The probe was verified in vitro. In vivo, all tooth surfaces could be imaged with the OCT probe, except the vestibular surfaces of third molars and the proximal surface sections of molars within a "blind spot" at a distance greater than 2.5 mm from the tooth surface. Proximal surfaces of 64 posterior teeth of four volunteers were assessed by intraoral OCT, visual-tactile inspection, bitewing radiography and fiber-optic transillumination. The agreement in detecting healthy and carious surfaces varied greatly between OCT and established methods (18.2-94.7%), whereby the established methods could always be supplemented by OCT. Direct and indirect composite and ceramic restorations with inherent imperfections and failures of the tooth-restoration bond were imaged and qualitatively evaluated. The intraoral OCT probe proved to be a powerful technological approach for the non-invasive imaging of healthy and carious hard tooth tissues and gingiva as well as tooth-colored restorations.

18.
Opt Lett ; 45(17): 4766-4769, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32870852

RESUMEN

While optical coherence tomography (OCT) provides a resolution down to 1 µm, it has difficulties in visualizing cellular structures due to a lack of scattering contrast. By evaluating signal fluctuations, a significant contrast enhancement was demonstrated using time-domain full-field OCT (FF-OCT), which makes cellular and subcellular structures visible. The putative cause of the dynamic OCT signal is the site-dependent active motion of cellular structures in a sub-micrometer range, which provides histology-like contrast. Here we demonstrate dynamic contrast with a scanning frequency-domain OCT (FD-OCT), which we believe has crucial advantages. Given the inherent sectional imaging geometry, scanning FD-OCT provides depth-resolved images across tissue layers, a perspective known from histopathology, much faster and more efficiently than FF-OCT. Both shorter acquisition times and tomographic depth-sectioning reduce the sensitivity of dynamic contrast for bulk tissue motion artifacts and simplify their correction in post-processing. Dynamic contrast makes microscopic FD-OCT a promising tool for the histological analysis of unstained tissues.

19.
J Biophotonics ; 13(10): e202000112, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32639647

RESUMEN

A method for numerical estimation and correction of aberrations of the eye in fundus imaging with optical coherence tomography (OCT) is presented. Aberrations are determined statistically by using the estimate based on likelihood function maximization. The method can be considered as an extension of the phase gradient autofocusing algorithm in synthetic aperture radar imaging to 2D optical aberration correction. The efficacy of the proposed method has been demonstrated in OCT fundus imaging with 6λ aberrations. After correction, single photoreceptors were resolved. It is also shown that wave front distortions with high spatial frequencies can be determined and corrected.


Asunto(s)
Algoritmos , Tomografía de Coherencia Óptica , Fondo de Ojo , Funciones de Verosimilitud
20.
Int J Comput Assist Radiol Surg ; 15(6): 1033-1042, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32383105

RESUMEN

PURPOSE: During endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated. METHODS: A multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue. RESULTS: The evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches. CONCLUSION: The results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Imagenología Tridimensional/métodos , Angiografía de Substracción Digital , Procedimientos Endovasculares/métodos , Fluoroscopía , Humanos , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...